Loum’s publications in 2017
Visual acuity in two-photon infrared vision
Autors: PABLO ARTAL, SILVESTRE MANZANERA, KATARZYNA KOMAR, ADRIÁN GAMBÍN-REGADERA, MACIEJ WOJTKOWSKI
Journal: Optica (OSA)
Volume: 4 (No. 12)
Pages: 1488 – 1491 (121488-04)
Year: 2017
ISBN: 2334-2536
Abstract
Humans can detect infrared light at wavelengths over 1000 nm, perceived as visible light of the corresponding half wavelength. This is due to a two-photon (2P) absorption process, which requires sufficiently large amounts […]
Design of an accurate and high-speed binocular pupil tracking system based on GPGPUs
Autors: Juan Mompeán, Juan L. Aragón, Pedro M. Prieto, Pablo Artal
Journal: The Journal of Supercomputing
Volume: 74 (Issue 5)
Pages: 1836–1862
Year: 2017
ISBN: 0920-8542 (online ISSN:1573-0484)
Abstract
An efficient and robust pupil tracking system is an important tool in visual optics and ophthalmology. It is also central to techniques for gaze tracking, of use in psychological and medical research, […]
Comparison of second harmonic microscopy images of collagen-based ocular tissues with 800 and 1045 nm
Autors: Juan M. Bueno, Francisco J. Ávila, and Pablo Artal
Journal: Biomedical Optics Express
Volume: 8 (11)
Pages: 5065-5074
Year: 2017
ISBN: 2156-7085
Abstract
Second harmonic generation (SHG) imaging is a well-suited multiphoton technique allowing visualization of biological tissues mainly composed of collagen with submicron resolution. Despite its inherent confocal properties, imaging of deeper layers within thick samples has still […]
Variability in angle k and its influence on higher-order aberrations in pseudophakic eyes
Autors: Annette Harrer, Nino Hirnschall, Juan Tabernero, Pablo Artal, Petra Draschl, Sophie Maedel, Oliver Findl
Journal: Journal of Cataract Refract Surgery
Volume: 43 (8)
Pages: 1015–1019
Year: 2017
ISBN: 0886-3350
Purpose: To observe the variability in angle k in pseudophakic
patients and assess its correlation with optical biometry measurements
and higher-order aberrations (HOAs).
Setting: Hanusch Hospital, Vienna, Austria.
Design: Prospective case series.
Methods: This study included patients who […]
Comparison of intraocular lens decentration and tilt measurements using 2 Purkinje meter systems
Autors: Sophie Maedel, Nino Hirnschall, Natascha Bayer, Sabine Markovic, Juan Tabernero, Pablo Artal, Frank Schaeffel, Oliver Findl
Journal: Journal of Cataract & Refractive Surgery
Volume: 43 (Issue5)
Pages: 648–655
Year: 2017
ISBN: 0886-3350
Purpose: To evaluate the difference in intraocular lens tilt and decentration measurements with 2 Purkinje meters.
Setting: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria.
Design: Prospective evaluation of […]
Scattering contribution to the double-pass PSF using Monte Carlo simulations
Autors: Dimitrios Christaras, Harilaos Ginis, Alexandros Pennos and Pablo Artal
Journal: Ophthalmic and Physiological Optics
Volume: 37 (Issue 3)
Pages: 342–346
Year: 2017
ISBN: 0275-5408
Abstract
Purpose
Scattering in the eye occurs mainly at two sites: the eye’s optical media and the deeper retinal layers. Although the two phenomena are often treated collectively, their spatial domain of contribution to the double-pass Point […]
Chromatic aberration control with liquid crystal spatial phase modulators
Autors: Jose L. Martinez, Enrique J. Fernandez, Pedro M. Prieto, And Pablo Artal
Journal: Optics Express
Volume: 25, Issue 9
Pages: 9793-9801
Year: 2017
ISBN: 1094-4087
Abstract:
The chromatic behavior of diffractive optical elements, exhibiting 2π-wrapped phase profiles, implemented into liquid crystal spatial light modulators (LC-SLM) is described. A wrapped phase map is only equivalent to the original continuous profile for […]
Micrometric Control of the Optics of the Human Eye: Environment or Genes?
Autors: Juan Tabernero, Lucía Hervella, Antonio Benito, Lucía Colodro-Conde, Juan R. Ordoñana, Marcos Ruiz-Sanchez, José María Marín, and Pablo Artal
Journal: IOVS
Volume: 58 (4)
Pages: 1964–1970
Year: 2017
ISBN: 0146-0404
PURPOSE. he human eye has typically more optical aberrations than conventional artificial optical systems. While the lower order modes (defocus and astigmatism) are well studied, our purpose is to […]
Achromatic doublet intraocular lens for full aberration correction
Autors:Enrique J. Fernandez, Pablo Artal
Journal: Biomedical Optics Express
Volume: 8 (Issue 5)
Pages: 2396-2404
Year: 2017
ISBN: 2156-7085
Abstract:
A doublet intraocular lens optimized for both chromatic and monochromatic aberration correction in pseudophakic eyes is presented. Ray-tracing techniques were applied to design the lens in white light within a chromatic eye model. Combinations of two materials, already commonly used in […]
Performance of a differential contrast sensitivity method to measure intraocular scattering
Autors: Alexandros Pennos, Harilaos Ginis, Augusto Arias,Dimitrios Christaras, and Pablo Artal
Journal: Biomedical Optics Express
Volume: 8, Issue 3
Pages: 1382-1389
Year: 2017
ISBN: 2156-7085
Abstract:
Increased intraocular scatter degrades quality of vision, especially in the presence of glare sources. Standard tests, such as visual acuity, are not well suited to capture this condition. There are specific methods to measure […]